6 - 37
14. WHEN STARTING SWITCH ON DOES NOT OPERATE
ş
Before disconnecting the connector, always turn the starting switch OFF.
ş
Before carrying out below procedure, check all the related connectors are properly inserted.
ş
After checking, insert the disconnected connectors again immediately unless otherwise specified.
Cause
Remedy
Disconnection in wiring
harness or poor
contact between
DO-2(1)-CR-1 or
defective battery relay
Disconnection in wiring
harness or poor
contact between
CS-2(2)-CN-1(M)-
DO-2(1)
Defective start
switch
Disconnection in wiring
harness or poor
contact between
CS-2(1)-CN-1(N)-CN-
60(1)- CR-1-Battery
Battery capacity
too low
Repair or replace
(After clean)
Replace
Replace
Replace
Charge or replace
(After clean)
Specific gravity : MIN 1.28
Voltage : MIN 24V
NO
Check voltage
and specific
gravity of battery
YES
YES
Voltage : 20~30V
Voltage : 20~30V
Voltage : 20~30V
YES
NO
YES
NO
NO
START SWITCH
CS-2
K
N
CN-1
1
2
3
4
5
6
C
1
2
3
4
5
6
ST
ACC
BR
H
H
O
I
II
I,O
B
DO-2
M
1
2
TO STARTER
FUSE
NO.11
START SAFETY RY
CR-5
CN-79
FUEL CUT -OFF
3
2
1
CN-3
A
B
4
3
2
1
E
S
I
F
1
2
3
4
CN-51
CPU CONTROLLER
1
MASTER SWITCH
2
1
BATTERY RY
CR-1
CN-60
Check voltage
between DO-2(1)
and chassis
Check voltage
between CS-2(2)
and chassis
Check voltage
between CS-2(1)
and chassis
Summary of Contents for R 160 LC-3
Page 9: ......
Page 142: ...4 4...
Page 182: ...4 44 No of pin Receptacle connector Female Plug connector Male 24 12 24 1 13 S815 024000...
Page 397: ......
Page 398: ......
Page 399: ......
Page 400: ......
Page 401: ......
Page 402: ......
Page 403: ......
Page 404: ......
Page 405: ......
Page 406: ......
Page 407: ......
Page 416: ...8 103 Remove lock nut 21 and then boot 26 15...
Page 427: ...8 114 Install cover 3 to hub 1 and tighten bolts 14 Torque 5 5 12 5kgf m 40 90lbf ft 7 14 15 3...
Page 456: ...8 143 1 STRUCTURE GROUP 11 WORKEQUIPMENT SECTION A SECTION B SECTION C C B B A A C...