5 - 24
2. OPERATING PRINCIPLE
STRUCTURE
1)
P
Pilot oil supply line(Pilot pressure)
T
Return to tank
A
Secondary pressure to flow regulator at hydraulic pump
AT H MODE
Pressure line is blocked and A oil returns to tank.
AT S, L, F MODE
Secondary pressure enters into A.
P
T
A
P
T
A
P
T
A
2
3
4
5
6
7
1
1
Sleeve
2
Spring
3
Spool
4
O-ring
5
O-ring
6
Solenoid valve
7
Connector
P
T
A
P
T
A
2)
3)