5- 34
5.MONITORING DISPLAY
OUTLINE
Information of machine performance as monitored by the CPU controller can be displayed on the
cluster when the operator selects a display mode by touching
SELECT
switch alone or with
BUZZER
STOP
switch on the cluster as below.
rpm
TIME
bar
bar
bar
bar
TIME
TIME
or
or
or
or
or
or
or
or
Initial
Touch
SELECT
1 time
Way 1
Key switch
ON
or
START
Way 2
Touch
AUTO DECEL
switch while pressing
BUZZER STOP
at
group 1~4.
Group 0
(Default)
Group 1
(Volt, temp,
EPPR press,
version)
Group 2
(Error code)
Group 3
(Switch input)
Group 4
(Output)
Touch
SELECT
switch
once while pressing
BUZZER STOP.
In this group
SELECT
LED
ON
Touch
SELECT
switch
twice while pressing
BUZZER STOP.
In this group
BUZZER
STOP
LED blinks
Touch
SELECT
switch
3 times while pressing
BUZZER STOP.
In this group
SELECT
LED blinks at 0.5sec
intervals
Touch
SELECT
switch
4 times while pressing
BUZZER STOP.
In this group
SELECT
LED blinks at 1sec
intervals
How to select display mode
Group selection
Display mode selection
Name
Display group
Display on the cluster
Option
(Only when
a pressure
sensor is
installed)
Engine rpm
Time
Front pump pressure
Rear pump pressure
Pilot pressure
Battery voltage(V)
Potentiometer voltage(V)
Hydraulic oil
temperature(
Ş
C)
Power shift pressure
(EPPR valve)
Model & Version
Current error
Recorded error
(Only key switch ON)
Recorded error deletion
(Only key switch ON)
Pump prolix switch
Auto decel pressure switch
Power boost switch
Travel oil pressure switch
Hourmeter
Neutral relay
(Anti-restart relay)
Travel solenoid
Power boost solenoid
(2-stage relief solenoid)
Default
Touch
SELECT
1 time
Touch
SELECT
2 times
Touch
SELECT
3 times
Touch
SELECT
4 times
Default
Touch
SELECT
1 time
Press speed up( ) &
speed down( ) at the
same time
Default
Touch
SELECT
1 time
Touch
SELECT
2 times
Touch
SELECT
3 times
Default
Touch
SELECT
1 time
Touch
SELECT
2 times
Touch
SELECT
3 times
Touch
SELECT
2 times
Touch
SELECT
3 times
Touch
SELECT
4 times
Ɠ
By touching SELECT switch once while pressing BUZZER STOP, display group shifts.
Example : Group 0 1 2 3 4 0
1)
Summary of Contents for R 160 LC-3
Page 9: ......
Page 142: ...4 4...
Page 182: ...4 44 No of pin Receptacle connector Female Plug connector Male 24 12 24 1 13 S815 024000...
Page 397: ......
Page 398: ......
Page 399: ......
Page 400: ......
Page 401: ......
Page 402: ......
Page 403: ......
Page 404: ......
Page 405: ......
Page 406: ......
Page 407: ......
Page 416: ...8 103 Remove lock nut 21 and then boot 26 15...
Page 427: ...8 114 Install cover 3 to hub 1 and tighten bolts 14 Torque 5 5 12 5kgf m 40 90lbf ft 7 14 15 3...
Page 456: ...8 143 1 STRUCTURE GROUP 11 WORKEQUIPMENT SECTION A SECTION B SECTION C C B B A A C...