6 - 54
TEST PROCEDURE
Test 13 : Check voltage at CN-51(3) and
ground.
Prepare 1 piece of thin sharp pin, steel or
copper.
Starting key ON.
Insert prepared pin to rear side of
connectors : One pin to (3) of CN-50.
Check voltage as figure.
15
CPU
CONTROLLER
CN-50
12
11
10
9
1
2
3
17 18 19
Multimeter
CN-50
20 21 22
4
5
6
13 14
7
8
16
23 24
PIN
Ground
(1)
ڸ
ڹ
ں
ڻ
2)
SPEC : Actuator stop : 4.5~5.5V