6 - 25
2. COMMUNICATION ERROR "Co : Err" FLASHES ON THE CLUSTER
ş
Before disconnecting the connector, always turn the starting switch OFF.
ş
Before carrying out below procedure, check all the related connectors are properly inserted.
ş
After checking, insert the disconnected connectors again immediately unless otherwise specified.
Cause
Remedy
Defective controller
Disconnection in
wiring harness or
poor contact
between CN-56
(3,4)-CN9(3,4)
Disconnection in
wiring harness or
poor contact
between CN-9
(3,4)-CN2(C,D)
Disconnection in
wiring harness or
poor contact
between CN-2
(C,D)-CN51(2.13)
Replace
Repair or replace
(After clean)
Repair or replace
(After clean)
Repair or replace
(After clean)
13
CLUSTER
POWER IG(24V)
GND
RX
TX
2
3
4
CN-56
2
3
4
CN-9
B
C
D
CN-2
CN-51
*4V
*12V
CONTROLLER
2
KEY ON
NO
NO
Check voltage
between CN-2
(C,D) and chassis
YES
YES
Check voltage
between CN-9
(3,4) and chassis
Check voltage
between CN-56
(3,4) and chassis
NO
YES
YES
NO
*4V
0V
*12V
0V
Check voltage
Summary of Contents for R 160 LC-3
Page 9: ......
Page 142: ...4 4...
Page 182: ...4 44 No of pin Receptacle connector Female Plug connector Male 24 12 24 1 13 S815 024000...
Page 397: ......
Page 398: ......
Page 399: ......
Page 400: ......
Page 401: ......
Page 402: ......
Page 403: ......
Page 404: ......
Page 405: ......
Page 406: ......
Page 407: ......
Page 416: ...8 103 Remove lock nut 21 and then boot 26 15...
Page 427: ...8 114 Install cover 3 to hub 1 and tighten bolts 14 Torque 5 5 12 5kgf m 40 90lbf ft 7 14 15 3...
Page 456: ...8 143 1 STRUCTURE GROUP 11 WORKEQUIPMENT SECTION A SECTION B SECTION C C B B A A C...