3 - 10
When the arm half flow switch is turned ON, the arm half flow solenoid valve is switched to ON and
Arm2 pilot port XAa2 is connect with drain line : So the spool of ARM2 is not actuated. As a result,
the arm in operation is only the ARM1 section. This function is useful to fine control of the arm in
case of finishing work.
5. ARM HALF FLOW SYSTEM
BOOM2
TRAVEL MOTOR
ARM CYLINDER
BOOM CYLINDER
SWING MOTOR
HYD
TANK
PILOT PUMP
BOOM1
BUCKRT CYLINDER
TRAVEL
SWING
ARM
BUCKET
BOOM
RCV PEDAL
RCV LEVER(LH)
RCV LEVER(RH)
RELIEF VALVE
SPIN
FILTER
LINE
FILTER
SAFETY
SOLENOID VALVE
ARM1
SWING
TRAVEL(RH)
ARM2
BUCKET
OPTION
TRAVEL(RH)
STRAINER
XAa2
XAa1
XAah
XAa1
XAah
ARM HALF
SOLENOID
VALVE
XAa2
Summary of Contents for R 160 LC-3
Page 9: ......
Page 142: ...4 4...
Page 182: ...4 44 No of pin Receptacle connector Female Plug connector Male 24 12 24 1 13 S815 024000...
Page 397: ......
Page 398: ......
Page 399: ......
Page 400: ......
Page 401: ......
Page 402: ......
Page 403: ......
Page 404: ......
Page 405: ......
Page 406: ......
Page 407: ......
Page 416: ...8 103 Remove lock nut 21 and then boot 26 15...
Page 427: ...8 114 Install cover 3 to hub 1 and tighten bolts 14 Torque 5 5 12 5kgf m 40 90lbf ft 7 14 15 3...
Page 456: ...8 143 1 STRUCTURE GROUP 11 WORKEQUIPMENT SECTION A SECTION B SECTION C C B B A A C...