Error messages 99
Drive Monitoring Features Are Unobtainable
Description
: ADU ("
Array diagnostic software
" on page
77
) is unable to get monitor and performance data
due to a fatal command problem (such as drive time-out), or is unable to get data due to these features not
being supported on the controller.
Action
: Check for other errors such as time-outs. If no other errors occur, upgrade the firmware to a version
that supports monitor and performance, if desired.
Drive Monitoring is NOT Enabled for SCSI Port X Drive ID Y
Description
: The monitor and performance features have not been enabled on this drive.
Action
: Run the server setup utility to initialize the monitor and performance features.
Drive Time-Out Occurred on Physical Drive Bay X
Description
: ADU issued a command to a physical drive and the command was never acknowledged.
Action
: The drive or cable may be bad. Check the other error messages on the Diagnostics screen to
determine resolution.
Drive X Indicates Position Y
Description
: Message indicates a designated physical drive, which seems to be scrambled or in a drive bay
other than the one for which it was originally configured.
Action
:
1.
Examine the graphical drive representation on ADU ("
Array diagnostic software
" on page
77
) to
determine proper drive locations.
2.
Power down the server.
3.
Remove drive
X
and place it in drive position
Y
.
4.
Rearrange the drives according to the ADU instructions.
Duplicate Write Memory Error
Description
: Data cannot be written to the array accelerator board in duplicate due to the detection of parity
errors. This is not a data-loss situation.
Action
: Replace the array accelerator board.
Error Occurred Reading RIS Copy from SCSI Port X Drive ID
Description
: An error occurred while ADU ("
Array diagnostic software
" on page
77
) was trying to read the
RIS from this drive.
Action
: HP stores the hard drive configuration information in the RIS. If multiple errors occur, the drive may
need to be replaced.
FYI: Drive (Bay) X is Third-Party Supplied
Description
: Third-party supplied the installed drive.
Action
: If problems exist with this drive, replace it with a supported drive.