Error messages 161
Processor Correctable Error Threshold Passed (Slot X, Socket Y)
Event Type
: Correctable error threshold exceeded
Action
:
CAUTION:
Before removing or replacing any processors, be sure to follow the guidelines
provided in "Performing processor procedures in the troubleshooting process (on page
17
)."
Failure to follow the recommended guidelines can cause damage to the system board, requiring
replacement of the system board.
Replace the processor.
Processor Uncorrectable Internal Error (Slot X, Socket Y)
Event Type
: Uncorrectable error
Action
:
CAUTION:
Before removing or replacing any processors, be sure to follow the guidelines
provided in "Performing processor procedures in the troubleshooting process (on page
17
)."
Failure to follow the recommended guidelines can cause damage to the system board, requiring
replacement of the system board.
Replace the processor.
Real-Time Clock Battery Failing
Event Type
: System configuration battery low
Action
: Replace the system configuration battery.
System AC Power Overload (Power Supply X)
Event Type
: Power supply overload
Action
:
1.
Switch the voltage from 110 V to 220 V or add an additional power supply (if applicable to the
system).
2.
If the problem persists, remove some of the installed options.
System AC Power Problem (Power Supply X)
Event Type
: AC voltage problem
Action
: Check for any power source problems.
System Fan Failure (Fan X, Location)
Event Type
: Fan failure
Action
: Replace the fan.