Error messages 153
SCSI Port Y: Side-Panel must be Closed to Prevent Overheating
SCSI Port Y: Redundant Power Supply Malfunction Detected
SCSI Port Y: Wide SCSI Transfer Failed
SCSI Port Y: Interrupt Signal Inoperative
SCSI Port y: Unsupported ProLiant Storage System Detected
Audible Beeps
: None
Possible Cause
: Environment threshold was violated on the drive enclosure.
Action
:
•
Check the cooling fan operation by placing a hand over the fan.
•
Be sure the internal plenum cooling fan in tower servers or storage systems is operational. If the fan is
not operating, check for obstructions and check all internal connections.
•
Replace the unit side panel if removed.
•
Check the LEDs. If the ProLiant Storage System power LED is amber instead of green, this indicates a
redundant power supply failure.
•
If the message indicates to check SCSI cables, do the following:
a.
Compare the cabling against the diagrams in the
HP Smart Array Controller User Guide
.
b.
If the routing is correct, replace cables on the specified port until the POST error message is
eliminated.
1778-Drive Array Resuming Automatic Data Recovery Process
Audible Beeps
: None
Possible Cause
: A controller reset or power cycle occurred while Automatic Data Recovery was in progress.
Action
: No action is required.
1779-Slot X Drive Array - Replacement drive(s) detected OR previously failed drive(s)
now operational:...
...Port Y: SCSI ID Z:
Restore data from backup if replacement drive X has been installed.
Audible Beeps
: None
Possible Cause
: More drives failed (or were replaced) than the fault-tolerance level allows. Unable to rebuild
array. If drives have not been replaced, this message indicates an intermittent drive failure.
Action
: Be sure the system is always powered up and down correctly:
•
When powering up the system, all external storage systems must be powered up before (or at the same
time as) the server.
•
When powering down the system, the server must be powered down before powering down any
external storage systems.