Error messages 155
1786-Disk 0 Software RAID Failure, Booting Disk 1
Audible Beeps
: None
Possible Cause
: The operating system has marked the RAID 1 bootable partition on Disk 0 as bad or the hard
drive has failed.
Action
: The system attempts to boot from Disk 1. Perform one of the following actions:
•
Replace the primary drive, if applicable, and re-mirror the data from the secondary drive.
•
Repair the logical drive. Refer to the operating system documentation.
1786-Slot 1 Drive Array Recovery Needed...
...The following SCSI drive(s) need Automatic Data Recovery: SCSI Port Y: SCSI ID Z
Select F1 to continue with recovery of data to drive. Select F2 to continue without recovery of data to drive.
Audible Beeps
: None
Possible Cause
: A failed or replacement drive has not yet been rebuilt.
Action
:
•
Perform one of the following actions:
o
Press the
F1
key to continue with recovery of data to the drive. Data will be automatically restored
to drive
X
when a failed drive has been replaced, or to the original drive if it is working again
without errors.
o
Press the
F2
key to continue without recovery of data to the drive. The failed drive will not be rebuilt
and the system will continue to operate in a failed state of Interim Data Recovery Mode.
•
Replace the failed drive and press the
F1
key to rebuild the array. If the drive rebuild is not successful or
is aborted because the system rebooted before the rebuild of the drive completed, another version of the
1786 POST error message will be displayed. Refer to the following message.
1786-Slot 1 Drive Array Recovery Needed. Automatic Data Recovery Previously
Aborted!...
...The following SCSI drive(s) need Automatic Data Recovery: SCSI Port Y: SCSI ID Z
Select F1 to retry Automatic Data Recovery to drive. Select F2 to continue without starting Automatic Data Recovery.
Audible Beeps
: None
Possible Cause
: System is in Interim Data Recovery Mode and a failed or replacement drive has not yet been
rebuilt. This message is displayed if the
F2
key was pressed during a previous boot or if the
F1
key was
pressed during a previous boot and the system rebooted before the rebuild of the drive completed.
Action
:
•
Perform one of the suggested actions:
o
Press the
F1
key to retry Automatic Data Recovery to the drive. Data will be automatically restored
to drive
X
when a failed drive has been replaced, or to the original drive if it is working again
without errors.
o
Press the
F2
key to continue without recovery of data to the drive. The failed drive will not be rebuilt
and the system will continue to operate in a failed state of Interim Data Recovery Mode.
•
If drive recovery is not successful, run ADU ("
Array diagnostic software
" on page
77
) for more
information.