Error messages 156
o
If the replacement drive failed, replace with another drive.
o
If the rebuild was aborted due to a read error from another physical drive in the array, back up all
readable data on the array, run ADU, and then restore the data.
1787-Drive Array Operating in Interim Recovery Mode...
...Physical drive replacement needed: Drive X
Audible Beeps
: None
Possible Cause
: Hard drive
X
failed or cable is loose or defective. Following a system restart, this message
notes that drive
X
is defective and fault tolerance is being used.
Action
:
1.
Be sure all cables are connected properly and securely.
2.
Test and replace defective cables.
3.
Replace drive
X
. (depending on the fault-tolerance level, all data may be lost if another drive fails).
1788-Slot X Drive Array Reports Incorrect Drive Replacement...
...The following SCSI drive(s) should have been replaced: SCSI Port Y: SCSI ID Z.
The following SCSI drive(s) were incorrectly replaced: SCSI Port y: SCSI ID z.
Select F1 to continue – drive array will remain disabled.
Select F2 to reset configuration – all data will be lost.
Audible Beeps
: None
Possible Cause
:
•
Replacement drives may have been installed in the wrong drive bays.
•
A bad power cable connection to the drive, noise on the data cable, or defective SCSI cable exists.
Action
:
•
If replacement drives are installed in the wrong bays, properly reinstall the drives as indicated and:
o
Press the
F1
key to restart the server with the drive array disabled.
o
Press the
F2
key to use the drives as configured and lose all the data on them.
•
If a bad power cable connection exists:
a.
Repair the connection and press the
F2
key.
b.
If the problem persists, run ADU ("
Array diagnostic software
" on page
77
) to resolve.
•
Be sure the cable is routed properly.
1789-Slot X Drive Array SCSI Drive(s) Not Responding...
...Check cables or replace the following SCSI drives: SCSI Port Y: SCSI ID Z
Select F1 to continue – drive array will remain disabled.
Select F2 to failed drives that are not responding – Interim Recovery Mode will be enabled if configured for fault
tolerance.
Audible Beeps
: None