Error messages 136
611-Primary Floppy Port Address Assignment Conflict
Audible Beeps
: 2 short
Possible Cause
: A hardware conflict in the system is preventing the diskette drive from operating properly.
Action
:
1.
Run the server setup utility to configure the diskette drive port address and manually resolve the conflict.
2.
Run Insight Diagnostics ("
HP Insight Diagnostics
" on page
76
) and replace failed components as
indicated.
612-Secondary Floppy Port Address Assignment Conflict
Audible Beeps
: 2 short
Possible Cause
: A hardware conflict in the system is preventing the diskette drive from operating properly.
Action
:
1.
Run the server setup utility to configure the diskette drive port address and manually resolve the conflict.
2.
Run Insight Diagnostics ("
HP Insight Diagnostics
" on page
76
) and replace failed components as
indicated.
1100 Series
1151-Com Port 1 Address Assignment Conflict
Audible Beeps
: 2 short
Possible Cause
: Both external and internal serial ports are assigned to COM
X
.
Action
: Run the server setup utility and correct the configuration.
1600 Series
1609 - The server may have a failed system battery. Some...
...configuration settings may have been lost and restored to defaults. Refer to server documentation for more
information. If you have just replaced the system battery, disregard this message.
Audible Beeps
: None
Possible Cause
: Real-time clock system battery has lost power. The system will lose its configuration every time
AC power is removed (when the system is unplugged from AC power source) and this message displays
again if a battery failure has occurred. However, the system will function and retain configuration settings if
the system is connected to the AC power source.
Action
: Replace battery (or add external battery).
1610-Temperature Violation Detected. - Waiting 5 Minutes for System to Cool
...Press Esc key to resume booting without waiting for the system to cool.
WARNING: Pressing Esc is NOT recommended as the system may shutdown unexpectedly.