Error messages 107
Description
: The cooling fan located in the external storage unit has failed.
Action
: Replace the fan.
Storage Enclosure on SCSI Bus X Indicated that the Fan is Degraded...
...SOLUTION: this condition usually occurs on enclosures with multiple fans and one of those fans has failed. Replace
any fans not operating properly.
Description
: One or more fans in the external storage unit have failed.
Action
: Replace the failed fans.
Storage Enclosure on SCSI Bus X Indicated that the Fan Module is Unplugged...
...SOLUTION: Make sure the fan module is properly connected.
Description
: A fan in the external storage unit is not connected properly.
Action
: Check and reseat all fan connections securely.
Storage Enclosure on SCSI Bus X - Wide SCSI Transfer Failed...
...SOLUTION: This may indicate a bad SCSI cable on bus X. Try replacing the cable.
Description
: A cable on bus X has failed.
Action
:
1.
Replace the failed cable.
2.
If the problem persists, contact an authorized service provider.
Swapped cables or configuration error detected. A configured array of drives...
...was moved from another controller that supported more drives than this controller supports.
SOLUTION: Upgrade the firmware on this controller. If this doesn’t solve the problem, then power down system and
move the drives back to the original controller.
Description
: You have exceeded the maximum number of drives supported for this controller, and the
connected controller was not part of the original array configuration.
Action
:
1.
Update the controller to the latest firmware version ("
Firmware maintenance
" on page
81
).
2.
If the problem persists:
Replace this controller with the original controller.
or
Replace this controller with a new controller that supports the number of drives in the array.
Swapped Cables or Configuration Error Detected. A Drive Rearrangement...
...was attempted while an expand operation was running. This is an unsupported operation.
SOLUTION: Power down system then move drives back to their original location. Power on system and wait for the
expand operation to complete before attempting a drive rearrangement.
Description
: One or more drive locations were changed while an expand operation was in progress.
Action
:
1.
Power down the server.