Error messages 147
Audible Beeps
: None
Possible Cause
: A problem exists with the storage enclosure redundant cabling. A single path was found to
drives that were previously connected redundantly.
Action
:
Check the storage box I/O module and cable to restore redundant paths to the drives, then do one of the
following:
•
If the redundant cables/paths were not purposefully removed, press
F1
to display this message on
reboot until the problem is resolved. The drives should be accessible through the remaining path.
•
If the redundant paths were purposefully removed, press
F2
to disable this message on all subsequent
reboots.
1739-Slot X Drive Array - Redundant Cabling Configuration is not as
recommended...
...Refer to product user guide.
Audible Beeps
: None
Possible Cause
: Incorrect redundant cabling configuration
Action
: For information on how to cable the device in a supported manner for dual-domain redundant path
support, see the product user guide.
1742-Slot X Drive Array - Previously Ejected Drive(s) Detected...
Select “F1” to continue ignoring these physical drives.
Select “F2” to add these physical & logical drive(s) to this controller.
Audible Beeps
: None
Possible Cause
: The system detects that the drives are still present during POST and that the user previously
requested the drives to be removed from the controller configuration information.
Action
: Do one of the following:
•
If the drives will be removed at a later time, press
F1
to continue ignoring the physical drives.
•
To cancel the remove request and add these physical and logical drives back to the controller, press
F2
.
1743-Slot X Drive Array - Logical Drive Erase Operation in Progress...
...Drives being erased are temporarily offline.
Audible Beeps
: None
Possible Cause
: The drives being erased are offline.
Action
: Do one of the following:
•
Wait for the erase process to complete before using the logical drive.
•
Abort the erase process using ACU ("
Array Configuration Utility
" on page
71
).
1744-Slot X Drive Array - Drive Erase Operation In Progress or Queued...
...The following disk drive(s) will be blank upon completion: (followed by a list of drives)