Error messages 172
Description
: The system encountered an NMI prior to this boot. The NMI source was "Uncorrectable cache
memory error."
Action
:
CAUTION:
Before removing or replacing any processors, be sure to follow the guidelines
provided in "Performing processor procedures in the troubleshooting process (on page
17
)."
Failure to follow the recommended guidelines can cause damage to the system board, requiring
replacement of the system board.
Replace the processor.
Insight Diagnostics processor error codes
MSG_CPU_RR_1
Event type
: Unable to divide and multiply with zero and infinity.
Action
:
•
Ensure proper ventilation and cooling for the server.
•
Ensure the processor heatsinks are attached correctly (do not remove them).
•
Check diagnostics and the Integrated Management Log (on page
77
) for heat-related events.
•
Upgrade to the latest versions of system BIOS and HP Insight Diagnostics (on page
76
).
CAUTION:
Before removing or replacing any processors, be sure to follow the guidelines
provided in "Performing processor procedures in the troubleshooting process (on page
17
)."
Failure to follow the recommended guidelines can cause damage to the system board, requiring
replacement of the system board.
•
Replace the processor.
MSG_CPU_RR_2
Event type
: A Pentium floating point bug exists.
Action
:
CAUTION:
Before removing or replacing any processors, be sure to follow the guidelines
provided in "Performing processor procedures in the troubleshooting process (on page
17
)."
Failure to follow the recommended guidelines can cause damage to the system board, requiring
replacement of the system board.
Replace the processor.
MSG_CPU_RR_3
Event type
: Coprocessor geometric series is out of range.
Action
:
•
Ensure proper ventilation and cooling for the server.