Error messages 152
1776-Slot X Drive Array - SCSI Bus Termination Error
...Internal and external drives cannot both be attached to the same SCSI port. SCSI port Y: Check cables
Audible Beeps
: None
Possible Cause
: External and internal connectors of the specified SCSI ports are connected to drives. The
indicated SCSI bus is disabled until this problem is resolved.
Action
: The SCSI bus is not properly terminated when internal and external drives are connected concurrently
to the same SCSI bus.
1.
Power down the server.
2.
Be sure the cables to the specified port are connected properly and securely ("
Loose connections
" on
page
19
).
3.
Reconfigure the drives to different SCSI ports.
1776-Slot X Drive Array - Shared SAS Port Connection Conflict Detected - Ports 1I,
1E: Storage connections detected on both shared internal and external ports.
...Controller selects internal port until connection is removed from one of the ports.
Audible Beeps
: None
Action
: For cable configuration information, refer to the controller documentation.
1776-Drive Array Reports Improper SCSI Port 1 Cabling
Audible Beeps
: None
Possible Cause
:
•
The integrated array enabler board failed.
•
The I/O board, drive backplane fan board, or drive backplane failed.
Action
:
1.
Replace the integrated array enabler board.
2.
Update the integrated Smart Array option to the latest firmware version ("
Firmware maintenance
" on
page
81
).
CAUTION:
Only authorized technicians trained by HP should attempt to remove the I/O board.
If you believe the I/O board requires replacement, contact HP Technical Support ("
Contacting
HP
" on page
177
) before proceeding.
3.
Reboot the server after replacing each item:
a.
Drive backplane fan board
b.
Drive backplane
c.
I/O board
1777-Slot X Drive Array - Storage Enclosure Problem Detected (followed by one or
more of the following)
(followed by one or more of the following):
...SCSI Port Y: Cooling Fan Malfunction Detected
SCSI Port Y: Overheated Condition Detected