Error messages 122
Node Interleaving disabled - Invalid memory configuration
Description
: Each node must have the same memory configuration to enable interleaving.
Action
: Populate each node with the same memory configuration and enable interleaving in RBSU.
No Floppy Drive Present
Audible Beeps
: None
Possible Cause
: No diskette drive is installed or a diskette drive failure has occurred.
Action
:
1.
Power down the server.
2.
Replace a failed diskette drive.
3.
Be sure a diskette drive is cabled properly, if a diskette drive exists.
No Keyboard Present
Audible Beeps
: None
Possible Cause
: A keyboard is not connected to the server or a keyboard failure has occurred.
Action
:
1.
Power down the server, and then reconnect the keyboard.
2.
Be sure no keys are depressed or stuck.
3.
If the failure reoccurs, replace the keyboard.
Parity Check 2 - System DIMM Memory
Audible Beeps
: None
Possible Cause
: An uncorrectable error memory event occurred in a memory DIMM.
Action
: Run Insight Diagnostics ("
HP Insight Diagnostics
" on page
76
) to identify failed DIMMs. Then, use the
DIMM LEDs to identify failed DIMMs and replace the DIMMs.
PCI Bus Parity Error, PCI Slot X
Audible Beeps
: None
Possible Cause
: A PCI device has generated a parity error on the PCI bus.
Action
: For plug-in PCI cards, remove the card. For embedded PCI devices, run Insight Diagnostics and
replace any failed components as indicated.
Power Fault Detected in Hot-Plug PCI Slot X
Audible Beeps
: 2 short
Possible Cause
: A PCI-X hot-plug expansion slot was not powered up properly.
Action
: Reboot the server.