Error messages 142
Audible Beeps
: None
Possible Cause
: Flash ROM is failing. The controller detects a checksum failure, but is unable to reprogram
the backup ROM.
Action
:
1.
Update the controller to the latest firmware version ("
Firmware maintenance
" on page
81
).
2.
If the problem persists, replace the controller.
1714-Slot X Drive Array Controller - Redundant ROM Reprogramming Failure
...Backup ROM has automatically been activated. Check firmware version.
Audible Beeps
: None
Possible Cause
: The controller flash operation is interrupted by a power cycle, or flash ROM is failing. The
controller detects a ROM checksum error and automatically switches to the backup ROM image.
Action
: If this backup ROM image is a lower version than the originally running image, update the controller
to the latest firmware version.
1715-Slot X Drive Array Controller - Memory Error(s) Occurred
...Warning: Corrected Memory Error(s) were detected during controller memory self-test...
Audible Beeps
: None
Possible Cause
: The memory is beginning to fail.
Action
: If this error persists, replace the controller.
1716-Slot X Drive Array Controller - Unrecoverable Media Errors Detected on Drives
...Errors will be fixed automatically when these sectors are overwritten. Backup and restore recommended.
Audible Beeps
: None
Possible Cause
: A media error is detected on a drive and cannot be corrected because of degraded fault
tolerance or a media error at the same location on another drive in the same array. An unrecoverable read
error is returned to the operating system when this block address is read.
Action
: Backup and restore the data on the drive. Sequential write operations to the affected blocks should
resolve the media errors.
1717-Slot X Drive Array Controller - Disk Drive(s) Reporting OVERHEATED Condition
Audible Beeps
: None
Possible Cause
: The drives listed in this message are currently in an overheated state.
Action
: Check the fans and be sure the air flows over the drive. Install the access panel, if removed.
1718-Slot X Drive Array Controller - Device discovery found more devices attached to
this controller than firmware currently supports...
...Some devices are ignored.