Error messages 96
Configuration Signature is Zero
Description
: ADU ("
Array diagnostic software
" on page
77
) detected that NVRAM contains a configuration
signature of zero. Old versions of the server setup utility could cause this.
Action
: Run the latest version of server setup utility to configure the controller and NVRAM.
Configuration Signature Mismatch
Description
: The array accelerator board is configured for a different array controller board. The
configuration signature on the array accelerator board does not match the one stored on the array controller
board.
Action
: To recognize the array accelerator board, run ACU ("
Array Configuration Utility
" on page
71
).
Controller Communication Failure Occurred
Description
: Controller communication failure occurred. ADU was unable to successfully issue commands to
the controller in this slot.
Action
:
1.
Be sure all cables are properly connected and working.
2.
Be sure the controller is working, and replace if needed.
Controller Detected. NVRAM Configuration not Present
Description
: EISA NVRAM does not contain a configuration for this controller.
Action
: Run the server setup utility to configure the NVRAM.
Controller Firmware Needs Upgrading
Description
: Controller firmware is below the latest recommended version.
Action
: Update the controller to the latest firmware version ("
Firmware maintenance
" on page
81
).
Controller is Located in Special "Video" Slot
Description
: Controller is installed in the slot for special video control signals. If the controller is used in this
slot, LED indicators on the front panel may not function properly.
Action
: Install the controller into a different slot, and run the server setup utility to configure NVRAM. Then, run
ACU ("
Array Configuration Utility
" on page
71
) to configure the controller.
Controller Is Not Configured
Description
: Controller is not configured. If the controller was previously configured and you change drive
locations, a problem might exist with the placement of the drives. ADU ("
Array diagnostic software
" on page
77
) examines each physical drive and looks for drives that have been moved to a different drive bay.
Action
: Look for messages indicating which drives have been moved. If no messages are displayed and drive
swapping did not occur, run ACU ("
Array Configuration Utility
" on page
71
) to configure the controller and
run the server setup utility to configure NVRAM.
Do not
run either utility if you believe drive swapping has
occurred.