Error messages 145
Audible Beeps
: None
Possible Cause
: The controller has detected an additional array of drives that was connected when the power
was off. The logical drive configuration information has been updated to add the new logical drives. The
maximum number of logical drives supported is 32. Additional logical drives will not be added to the
configuration.
Action
: No action is required.
1729-Slot X Drive Array - Performance Optimization Scan In Progress
...RAID 4/5/ADG performance may be higher after completion.
Audible Beeps
: None
Possible Cause
: One or more RAID 4/5/ADG parity drives are being initialized. Performance of the
controller improves after the parity data has been initialized by ARM, an automatic process that runs in the
background on the controller.
Action
: No action is required.
1732-Slot X Drive Array - Array Accelerator Battery Pack Missing...
...Array Accelerator Posted-Write Cache is permanently disabled. Array Accelerator will be reenabled when
additional battery packs are installed.
Audible Beeps
: None
Possible Cause
: Battery packs are detached from the controller or have failed.
Action
: Check the battery pack to be sure the connection is secure. If the condition persists, then install a
replacement battery pack.
1733-Slot X Drive Array - Storage Enclosure Firmware Upgrade Problem Detected...
...Port x box y: Enclosure firmware upgrade needed - run Flash Components.
Port x box y: Unable to read firmware version of one or more components
Audible Beeps
: None
Possible Cause
: An incorrect enclosure firmware version is installed, or an enclosure firmware upgrade is
needed.
Action
:
•
Upgrade the enclosure firmware and the controller firmware.
•
If the condition persists, then replace the enclosure components.
For more information, see the
HP BladeSystem c-Class Enclosure Troubleshooting Guide
on the HP website
(
http://www.hp.com/support/BladeSystem_Enclosure_TSG_en
).
1735-Slot z Drive Array - Unsupported Redundant Cabling Configuration Detected...
...Multiple paths to the same enclosure/drives are not supported by this Smart Array firmware version. Access to all
drives has been disabled until redundant SAS cable(s) are detached, or firmware is updated to a version that supports
dual-domain.