Software problems 65
ROM problems
Remote ROM flash problems
General remote ROM flash problems are occurring
Action
: Be sure you follow these requirements for using the Remote ROM flash utility:
•
A local administrative client system that is running the Microsoft® Windows NT® 4.0,
Windows® 2000, or Windows Server™ 2003 operating system
•
One or more remote servers with system ROMs requiring upgrade
•
An administrative user account on each target system. The administrative account must have the same
username and password as the local administrative client system.
•
All target systems are connected to the same network and use protocols that enable them to be seen
from the administrative client.
•
Each target system has a system partition that is at least 32 MB in size.
•
Verification that the ROM version to which you are upgrading can be used for all the servers or array
controllers that you are upgrading.
•
Follow the instructions for the Remote ROM Flash procedure that accompany the software.
Command-line syntax error
If the correct command-line syntax is not used, an error message describing the incorrect syntax is displayed
and the program exits. Correct the syntax, and then restart the process.
Access denied on target computer
If you specify a networked target computer for which you do not have administrative privileges, an error
message is displayed describing the problem, and then the program exits. Obtain administrative privileges
for the target computer, and then restart the process. Be sure the remote registry service is running on a
Windows®-based system.
Invalid or incorrect command-line parameters
If incorrect parameters are passed into command-line options, an error message describing the invalid or
incorrect parameter is displayed and the program exits (Example: Invalid source path for system
configuration or ROMPaq files). Correct the invalid parameter, and then restart the process.
Network connection fails on remote communication
Because network connectivity cannot be guaranteed, it is possible for the administrative client to become
disconnected from the target server during the ROM flash preparation. If any remote connectivity procedure
fails during the ROM flash online preparation, the ROM flash does not occur for the target system. An error
message describing the broken connection displays and the program exits. Attempt to ascertain and correct
the cause of connection failure, and then restart the process.