Error messages 115
Logical drive state: The logical drive is queued for expansion.
Action
: No action is required.
Logical drive state: The logical drive is queued for rebuilding.
Action
: No action is required. Normal operations can occur; however, performance will be less than optimal
during the rebuild process.
Logical drive state: This logical drive has a high physical drive count...
...as well as a high stripe size value such that a controller lock up could occur. It is recommended that the stripe size be
migrated to a lower value.
Action
: Migrate the stripe size to a lower value using the Array Configuration Utility (on page
71
).
NVRAM Error: Board ID could not be read...
...(Read-Only Table failed checksum test). Unrecoverable error.
Action
: Contact HP support ("
Contacting HP
" on page
177
).
NVRAM Error: Bootstrap NVRAM image failed checksum test,...
...but a backup image was found and successfully restored. A system restart is needed.
Action
: Restart the server.
NVRAM Error: Bootstrap NVRAM image failed checksum test...
...and could not be restored. This error may or may not be recoverable. A firmware update might be able to correct the
error.
Action
: Update the controller firmware. If the update fails, contact HP support ("
Contacting HP
" on page
177
).
Physical Drive State: The data on the physical drive is being rebuilt.
Action
: No action is required. Normal operations can occur; however, performance will be less than optimal
during the rebuild process.
Physical Drive State: This drive is not supported for configuration...
...and should be disconnected from this controller.
Action
: Replace the physical drive with a drive supported by the controller.
Redundancy State: This controller has been setup to be part of a redundant pair of
controllers....
...but redundancy is temporarily disabled. Redundancy is temporarily disabled because capacity expansion,
extension, or migration is in progress. Redundancy will be enabled when this process is complete.
Action
: No action is required.