Cisco B200 M3 Blade Server
Statement of Volatility
Publication Date: November 19, 2013
The Cisco B200 M3 blade server has multiple serial, electrically erasable, and programmable nonvolatile
memory components (EEPROM and Flash memory) that are used to store manufacturing hardware
identification and hardware configuration information. The majority of serial EEPROMs and flash
memories are not written by users and contain no customer information. Procedures for clearing the few
flash devices that can retain customer data are included in this document.
•
Restoring the BIOS to the Factory Default Settings
•
Restoring the LSI SAS Controller to the Factory Default Settings
•
Restoring the CIMC to the Factory Default Settings
•
Resetting the CMOS From UCS Manager
Restoring the BIOS to the Factory Default Settings
Use the following procedure to restore the BIOS to the factory default settings through the UCS Manager
remote KVM or a local KVM I/O cable that is connected directly to the blade server.
Step 1
Press
F2
to access the BIOS setup.
Step 2
Click the
Save and Exit
tab.
Step 3
On the Save and Exit tab, click
Load Default Values
.
Step 4
Click
Yes
.
Step 5
Click
Save and Exit
or press
F10.
Step 6
Click
Yes
to reboot the blade server.