C O N F I G U R I N G M A X P R O N V R
Configuring the Cameras
MAXPRO NVR 3.1 Operator’s Guide
87
2.
Click the
I/O
tab to open the
I/O
page.
Figure 4-12 IO page
3.
The
Input(s)
pane lists the inputs for the configured cameras. Select the appropriate
options in the fields as explained in the following table.
Field
Description
Global Event ID
Unique event ID
Name
External input name.
Enable/Disable
Enables or Disables the input.
Camera
Displays the associated camera name.
State (CLOSED/OPEN)
The default option is
CLOSED
.
Defines the normal (non-alarm or non-active) state of
the input. For example a normally closed input would
have its input terminal normally connected to common
or ground. To activate the normally closed input, the
input needs to be opened (connection to ground or
common removed). For example: A magnetic door
switch raises alarm if the contacts are open when the
door opens.
Record (No/Yes)
The default option is
No
. If set to
Yes
recording will
starts when an input is activated.
Note
Recording is based on the time you set under
System
tab >
Event recording settings
. You
can specify the
Pre-event time
and
Record For
time to record the video.
Trigger
(NONE/ControlOutput)
The default option is
NONE
. If a control output is
selected, then the selected output is activated when the
corresponding input activates.
Note
A cameras input can only activate the same
cameras output.
Summary of Contents for MAXPRO
Page 1: ...Document 800 16422V1 Rev E 8 2014 MAXPRO NVR 3 1 Operator s Guide ...
Page 2: ...This page is intentionally left blank ...
Page 4: ...This page is intentionally left blank ...
Page 15: ...Index 249 ...
Page 16: ...This page is Intentionally left blank ...
Page 20: ...This page is Intentionally left blank ...
Page 254: ...I N D E X 254 MAXPRO NVR 3 1 Operator s Guide This page is intentionally left blank ...
Page 255: ......