15-57
[3]
BRUSH
ASSEMBLY
[5]
BRUSH
HOLDER A
[9]
BLUE
WIRE
[8]
TERMINAL
[7]
GREEN WIRE
[6] PLIERS
[1]
FRONT
BRACKET
ASSEMBLY
[4]
MOTOR
WIRES
[3]
YOKE ASSEMBLY
[1]
SHOP
TOWEL
[2]
ARMATURE
[6]
4 x 16 mm
SCREW
[10]
BREAKER
ASSEMBLY
[2]
BRUSH
SPRINGS
[4]
PROJECTION
[4]
PROJECTION
[5] FRONT BRACKET
ASSEMBLY
d. ASSEMBLY
• When the front bracket assembly is replaced with the new
one, remove the 4 x 10 mm screw that secures the brush
holder B.
1) Install the new O-ring and the oil seal on the front bracket
Apply heat resisting grease to the oil seal lip.
2) Connect the motor wire (blue wire) terminal to the breaker
assembly terminal.
3) Check the magnet in the yoke assembly for washer and
other foreign material. There must be no washer, etc. on
the magnet.
Set the brush assembly terminal above the motor wire
(green wire) terminal and loosely tighten the 4 x 10 mm
screw. Be sure that the motor wire (green wire) terminal
and the brush assembly wire terminal contact the
respective projections on the brush holder A, then tighten
the 4 x 10 mm screw securely.
4) Check that the commutator surface is not contaminated
with oil and grease. Set the two brush springs on the front
bracket assembly and install the armature on the front
bracket with the brush terminal pushed in the holder.
5) Wrap the armature shaft with a shop towel or equivalent
material and hold the shaft with the pliers.
6) Pulling the two motor wires of the yoke assembly side
slowly, install the armature/front bracket assembly on the
yoke assembly.
If it is hard to install the armature/front bracket assembly on
the yoke assembly, check whether the metal of yoke
assembly (i.e. where the armature shaft is installed) is out
of position and repeat the procedure from step 4.
7) Check that the armature turns smoothly and tighten the
two 4 x 16 mm screws.
After tightening the two 4 x 16 mm screws, connect the
power tilt motor 2P connector and check whether the motor
turns.
If the motor does not turn, disassemble the power tilt
motor assembly again, and check whether the motor wire
(blue wire) terminal is disconnected.