BF135A•BF150A
5-147
b. REPLACEMENT
1) Disconnect the low pressure side EOP switch terminal.
2) Remove the EOP switch.
3) Clean the EOP switch installation section in the crankcase.
4) Apply the liquid gasket (ThreeBond
®
#1215 or equivalent) to
the indicated area of the threads of the new EOP switch.
5) Install and tighten the EOP switch to the specified torque.
TORQUE: 8 N
•
m (0.8 kgf
•
m, 6 lbf
•
ft)
•
Be sure to use the torque wrench to tighten the EOP
switch.
•
Do not exceed the specified torque when tightening the
EOP switch. Overtightening will damage the cylinder
block.
6) Connect the EOP switch terminal.
NOTICE
18. ECT (ENGINE COOLANT
TEMPERATURE) SENSOR 1
a. REPLACEMENT
1) Disconnect the 2P connector of ECT sensor 1.
2) Remove the ECT sensor 1 and the O-ring.
• Replace the O-ring on assembly.
3) Apply the engine oil to the new O-ring and install it on the
ECT sensor 1.
4) Tighten the ECT sensor 1 to the specified torque.
TORQUE: 12 N
•
m (1.2 kgf
•
m, 9 lbf
•
ft)
5) Connect the ECT sensor 1 connector.
[1] EOP SWITCH
[1]
LIQUID GASKET
APPLICATION AREA
[2]
ECT SENSOR 1
CONNECTOR
[3]
ECT SENSOR 1
[1]
13 x 1.5 mm O-RING
Do not reuse.