89
Step 2
Turn on all the power switches of the Device.
Figure 4-21 Turning on the power
(1) Power switch
NOTE
Set all power switches to on within five seconds of turning the first switch on. If you take
longer than five seconds, the control and switching unit detects a power failure, and the
failure information is displayed on the LCD display.
If this happens, take action as described in the following table.
Display on the LCD
display
Procedure
E8 PS
Msg=00000001
The Device is ready.
Turn on all power switches.
(When the power failure is resolved, the information on the
LCD display disappears.)
[MD] FAULT 2200
220000aa00bb
The Device is unable to start operation because the power
supply capacity is insufficient.
Turn off all power switches, and then turn them on again.
The values for aa and bb above vary depending on the installation status of the power
supply unit and the status of the power supply.
NOTE
Wait at least two seconds between turning off the power and turning it back on again.