366
26014513
INFO
SP
Login refused for too
many users logged in.
15
An attempt to log in to the SP was made, but connection was not
permitted because the maximum allowed number of login users
was exceeded.
[Explanation of the message text]
None.
[Action]
Use the
netstat
command to check the number of users who
are currently logged in.
This message is output
when an attempt is made to
log in to the SP from BCU by
using telnet beyond the
maximum login number (20
sessions), or when an
attempt is made to directly
connect to the SP
management port and log in
by using telnet.
22014411
Port
<port no>
:Error
detected on management
port.
WARNING SP
16
A line failure occurred on the management port
<port no>
.
[Explanation of the message text]
<port no>
: Port number
[Action]
1. If the cable is disconnected or not fully inserted, connect the
cable correctly.
- This message is output
when the management port
is in
interface up
status
and the cable becomes
disconnected.
- This message is output
when the management port
cable is disconnected and
the status changes to
interface up
.
22014412
Port
<port no>
:Error
recovered from
management port.
INFO
(WARNING
recovery)
SP
17
The line failure occurred on the management port
<port no>
was
recovered.[Explanation of the message text]
<port no>
: Port number
[Action]
None.
This message is output
when the state is detected in
which the management port
is in interface up status and
the cable is connected, after
a line failure is detected on
the management port.
This message is output
when the state changes to
interface down regardless of
whether the cable is
connected or disconnected
after a line failure is detected
on the management port.
Summary of Contents for GX1000-SMC013X
Page 94: ...94 5 Configuration Guide 5 1 Base Software Configuration Guide ...
Page 105: ...105 7 Access Lists 7 1 Access lists ...
Page 153: ...153 8 Policy Based Switching 8 1 Policy based switching ...
Page 165: ...165 9 Policy Based Routing 9 1 Policy based routing ...
Page 177: ...177 Figure 10 1 Overview of mode transitions ...
Page 213: ...213 17 MIB Reference 17 1 Private MIBs 17 2 Supported MIB Traps ...
Page 229: ...229 H W BOOT 11 44 MISC 1 0 SPCT 0 34 10 The updating of the SP files is finished ...
Page 451: ...451 28 Additional Information ...