4.7 Setting Automatic Saving
104
1
2
(Open/confirm the setting information.)
Select the data you want to save.
Setting options (
∗
. default setting)
(*1):After you select the data, “(after meas.)” is displayed
for the High-speed Function and “(realtime)” is displayed
for the Real-time Function. (If you select
[Off]
, proceed to
step 8.)
Off
∗
, Waveform(*1), CSV(*1), Calc(after meas.),
Wa Calc, CSV + Calc
In the following steps, use the same operation to con-
figure settings.
2
3
4
5
Select the
[Setting]
screen.
For real-time saving, this field dis-
plays an approximate time of which
in length the storage device insert-
ed in the instrument can store data.
3
When you want to specify the name of the
waveform file:
Specify a name in
[File Name]
.
See:
"4.10 Entering Comments and Titles" (p. 128)
If left blank, file names are created automatically.
See:
"Appendix 3 File Naming" (p. A12)
4
When you want to use both a CF card and
USB flash drive:
Set
[Media
(Preferred Save Location)
].
(default setting: CF)
If you selected
[Calc (after meas.)]
for the data to
save, proceed to step
8
.
5
Set
[Deleting
(Delete while Saving)
].
Select the desired operation when removable storage
becomes full while saving.
Setting options (
∗
. default setting)
Off
∗
Saving ends when the removable storage is near-
ly full.
On
When the free capacity of the removable storage
reaches a certain minimum size, waveform files
are deleted, oldest first. If deletion is not possible,
saving stops.
A file other than a waveform file is not applicable
for deletion. (Numerical calculation file, setting
configuration file, file created with other than
MR8880-20, etc.)
In the case of CSV (real time),
saving is possible when the re-
cording interval is set to 5 ms or
longer.
If the storage media set as the
preferred save location be-
comes full, the data will be au-
tomatically saved to the other
storage media.
Summary of Contents for MR8880-20
Page 2: ......
Page 12: ...Procedure 2 ...
Page 40: ...1 3 Screen Configuration and Display 30 ...
Page 76: ...3 4 Measurement Using Setting Wizard PRESETS key 66 ...
Page 174: ...6 4 Data Management 164 ...
Page 186: ...7 7 Performing a Printer Check 176 ...
Page 196: ...8 4 Numerical Value Calculation Expressions 186 ...
Page 216: ...10 4 Making System Settings 206 ...
Page 222: ...11 3 Communication Using Commands 212 4Click Next to start install ing Installing Click ...
Page 226: ...11 3 Communication Using Commands 216 ...
Page 254: ...13 6 Setting Wizard Function PRESETS 244 ...
Page 292: ...Appendix 10 Installing Waveform Viewer A30 ...
Page 297: ......
Page 298: ......
Page 299: ......
Page 300: ......