2. Wiring and connection
2-11
2) Connect single-phase AC380~440[V] to the control circuit terminals r and t according
to the model's voltage specification.
3) Connect the regenerated resistance between the terminals P and B.
4) At the U, V and W terminal, connect the U, V and W phase of the servo motor.
5) Ground the FG terminal. Connect the grounding wire of the servo motor with this
terminal.
AC SERVO
operating
device
FDA7020-H
FDA7030-H
FDA7045-H
FDA7075-H
FDA7110-H
FDA7150-H
Wire
thickness
AWG #12
(3.5mm
2
)
AWG #11 (4.2mm
2
)
AWG #8 (8mm
2
)
AWG #6
(14mm
2
)
AWG #4
(22mm
2
)
Open/close
device
GMC-12 (13A)
GMC-40(35A)
MC-40(40A)
MC-50(50A)
Breaker
ABS33b (10A)
ABS33b (20A)
ABS53b (40A)
ABS53b (50A)
Noise filter
ET3RE-4030 (30A)
ET3RB-4040
ET3RB-4060
External
regenerated
resistance
250W 40
(Drawing A)
250W 40
parallel 2 units
(Drawing A)
1.6kW 15Ω
(Drawing C)
2kW 15Ω
(Drawing C)
♥ Open/close device and Breaker : LS Industrial Systems,
♥ NOISE FILTER : Woonyoung(http://woonyoung.com), OKY (
),
ORIENT(
M4
∮4.3
Length :300
220
239
30
60
<
Drawing
A>
<
Drawing
B> Order Code : FDA500010S(1000W/6.25Ω)
Summary of Contents for FDA7000 Series
Page 42: ...1 Model check and handling 1 35...
Page 57: ...2 Wiring and connection 2 14 Drawing C Order Code Please contact our sales office...
Page 130: ...3 Parameter setting 3 51...
Page 167: ...5 Servo operating 5 10...
Page 188: ...8 External view 8 2 External view B CN1 CN3 CN2 External view C...
Page 189: ...8 External view 8 3 External view D External view E...
Page 190: ...8 External view 8 4 External view F External view G...
Page 192: ...8 External view 8 6 External view I External view J...
Page 193: ...8 External view 8 7 External view K External view L...
Page 194: ...8 External view 8 8 External view M...
Page 195: ...8 External view 8 9...