2. Wiring and connection
2-9
AC SERVO
operating
device
FDA7015/
FDA7015B
FDA7020/
FDA7020B
FDA7030/
FDA7030B FDA7045
FDA7075
FDA7110
FDA7150
Wire
thickness
AWG #12
(3.5mm2)
AWG #10
(5.5mm2)
AWG #8
(8mm2)
AWG #6
(14mm2)
AWG #4
(22mm2)
Open/close
device
GMC-40(35A)
GMC-50(50A)
GMC-85(80A)
GMC-100(100A)
Breaker
ABS33b
(10A)
ABS33b
(20A)
ABS33b(30A)
ABS53b
(50A)
ABS63b
(60A)
ABS103b(100A)
Noise filter
NFZ-4030SG(30A)
NFZ4040
SG(40A)
FT3RE-4060
(60A)
FT3RE-4080
(80A)
External
regenerated
resistance
250W 25
(Drawing A)
250W 25
parallel 2 units
(Drawing A)
250W 25Ω
parallel 4
units
(Drawing B)
800W 8Ω
parallel 2
units
(Drawing C)
1kW 6Ω
parallel 2 units
(Drawing C)
♥ Open/close device and Breaker : LS Industrial Systems,
♥ NOISE FILTER : Woonyoung(http://woonyoung.com), OKY (
),
ORIENT(
M4
∮4.3
Length :300
220
239
30
60
<Drawing A>
<Drawing B> Order Code : FDA500010S(1000W/6.25Ω)
Summary of Contents for FDA7000 Series
Page 42: ...1 Model check and handling 1 35...
Page 57: ...2 Wiring and connection 2 14 Drawing C Order Code Please contact our sales office...
Page 130: ...3 Parameter setting 3 51...
Page 167: ...5 Servo operating 5 10...
Page 188: ...8 External view 8 2 External view B CN1 CN3 CN2 External view C...
Page 189: ...8 External view 8 3 External view D External view E...
Page 190: ...8 External view 8 4 External view F External view G...
Page 192: ...8 External view 8 6 External view I External view J...
Page 193: ...8 External view 8 7 External view K External view L...
Page 194: ...8 External view 8 8 External view M...
Page 195: ...8 External view 8 9...