3. Parameter setting
3-10
Setting value
Contents
0
Extended Mode Bus (HIGEN Standard): Data Field
Configuration 4 bytes
1
Standard Modbus: Data Field Configuration 2bytes
For more information, please refer to MODBUS MANUAL on our website
(http://www.higenmotor.co.kr).
P01-23
*
Single turn offset
Unit
-
Setting range
0 ~ 131072
Manufactured
default
0
Speed/Torque/
Position control
When P01-20 [Absolute origin] is ON, the current single-turn data is automatically saved in this
parameter and initialized with StE-16 [Single-turn data] = 0.
P01-24
Parameter RAM Save
Unit
-
Setting range
0 ~ 3
Manufactured
default
0
Speed/Torque/
Position control
You can change the storage area of specific parameters. Parameters stored in the RAM area
are returned to their initial values when the power is turned on again. If you frequently set
parameters using Modbus communication, they can be used to protect ROM life.
* FDA7000 Servo Drive Internal ROM Write Life: 100,000 Times
Value
Function
0
Save all parameters to ROM
1
Save digital input speed / torque (P04-01 ~ P04-14) setting to RAM
2
Save Electronic gear ratio (P05-12~P05-19)) setting to RAM
3
Save digital input speed / torque (P04-01 ~ P04-14) and Electronic gear ratio (P05-
12~P05-19)) setting to RAM
Summary of Contents for FDA7000 Series
Page 42: ...1 Model check and handling 1 35...
Page 57: ...2 Wiring and connection 2 14 Drawing C Order Code Please contact our sales office...
Page 130: ...3 Parameter setting 3 51...
Page 167: ...5 Servo operating 5 10...
Page 188: ...8 External view 8 2 External view B CN1 CN3 CN2 External view C...
Page 189: ...8 External view 8 3 External view D External view E...
Page 190: ...8 External view 8 4 External view F External view G...
Page 192: ...8 External view 8 6 External view I External view J...
Page 193: ...8 External view 8 7 External view K External view L...
Page 194: ...8 External view 8 8 External view M...
Page 195: ...8 External view 8 9...