2. Wiring and connection
2-6
2.2.2. Medium type servo drive
[ FDA7004/7004B ~ FDA7010 Terminal ]
The usage and wiring method of FDA7004/7004B~FDA70010 are as follows.
1) As the main power of the power circuit, connect the R,S and T terminal to 3 phase
AC200~230[V].
2) As the auxiliary power of the power circuit, connect the r and t terminal to single phase
AC200 ~ 230[V].
3) Connect the recovery resistance of internal type during shipment between the
terminals P and B.
4) At the U, V and W terminal, connect the U, V and W phase of the servo motor.
5) Ground the FG terminal. Connect the grounding wire of the servo motor with this
terminal.
6) When main power is DC voltage, supply DC280~325[V] between “P[+]” and “N[-]”.
7) Don’t supply AC power between “P[+]” and “N[-]”.
AC SERVO
Operating device
FDA7004B
FDA7004
FDA7005
FDA7010
Wire thickness
AWG #16(1.25mm2)
AWG #14
(2.0mm2)
AWG #12 (3.5mm2)
Open/close device
GMC-12(13A) level
product
GMC-40(35A) level product
Breaker
ABS33b(5A) level product
ABS33b (10A)
level product
Noise filter
P3B4010-DA(10A) level product
NFZ-4030SG
(30A)level product
Regenerated
resistance
50W 50
External
resister
70W 50
Internal resister
♥ Open/close device and Breaker : LS Industrial Systems,
♥ NOISE FILTER : Woonyoung(http://woonyoung.com), OKY (
),
ORIENT(
Summary of Contents for FDA7000 Series
Page 42: ...1 Model check and handling 1 35...
Page 57: ...2 Wiring and connection 2 14 Drawing C Order Code Please contact our sales office...
Page 130: ...3 Parameter setting 3 51...
Page 167: ...5 Servo operating 5 10...
Page 188: ...8 External view 8 2 External view B CN1 CN3 CN2 External view C...
Page 189: ...8 External view 8 3 External view D External view E...
Page 190: ...8 External view 8 4 External view F External view G...
Page 192: ...8 External view 8 6 External view I External view J...
Page 193: ...8 External view 8 7 External view K External view L...
Page 194: ...8 External view 8 8 External view M...
Page 195: ...8 External view 8 9...