6. Troubleshooting and check
6-2
Abnormal
noise is
generated.
Coupling defect
Check the screw condition
of the coupling and copper
core of the connection
part etc.
Readjust the coupling.
Bearing problem
Check the bearing
vibration and abnormal
noise.
Contact our company.
Parameter mis-
setting(Motor/encoder
ID, inertia ratio, gain,
TC)
Check the control
parameter.
Refer to parameter setting
method in chapter 3.
6.1.2. Servo drive
When an alarm occurs in servo drive and error signal output contact point (ALARM) goes OFF
and the motor is stopped by dynamic brake.
Display
Content
Cause
Corrective Actions
nor
Normal
condition
Ano-00
EMER STOP
Emergency
stop
Turn external ESTOP
contact point input OFF.
Check external DC 24V power.
Check ESTOP contact point ON
status
Ano-01
OVER CURNT Over-current
Servo drive output terminal
(U, V, W) short circuit,
output over-current
Check output terminal wiring, re-
operate after resetting, replace drive
when O.C continues
Ano-02
OVER VOLT
AC link over-
voltage
Input over-voltage
(280V or above)
Regenerated resistance
burnt, Overload GD
2
Use input voltage of 230V or below
Replace brake resistance, increase
acceleration/deceleration time,
replace servo drive
Ano-03
OVER LOAD
Overload
Mechanical overload
Motor mis-wiring
Check load condition, check motor
and encoder wiring
Ano-04
POWER FAIL
Main power
issue
Main power blocked when
SERVO is ON
Check 3 phase main power (R, S, T)
input condition
Ano-05
LINE FAIL
Mis-wiring of
motor and
encoder
Motor and encoder related
set value error, motor and
encoder mis-wiring,
encoder defect,
mechanical overload
Check motor, encoder, wiring and
set value, remove overload
Ano-06
OVER SPEED
Over-speed
Over-gain, parameter set
value error,
over gravity load
Adjust gain
Check parameter (P03-15, P03-16)
Remove over gravity load
Summary of Contents for FDA7000 Series
Page 42: ...1 Model check and handling 1 35...
Page 57: ...2 Wiring and connection 2 14 Drawing C Order Code Please contact our sales office...
Page 130: ...3 Parameter setting 3 51...
Page 167: ...5 Servo operating 5 10...
Page 188: ...8 External view 8 2 External view B CN1 CN3 CN2 External view C...
Page 189: ...8 External view 8 3 External view D External view E...
Page 190: ...8 External view 8 4 External view F External view G...
Page 192: ...8 External view 8 6 External view I External view J...
Page 193: ...8 External view 8 7 External view K External view L...
Page 194: ...8 External view 8 8 External view M...
Page 195: ...8 External view 8 9...