3. Parameter setting
3-23
P03-08
SC TC 2
Unit
ms
Setting range
0.0 ~ 10000.0
Manufactured
default
By capacity
Speed/position
control
P03-09
Analog CMD TC
Unit
ms
Setting range
0.0 ~ 2000.0
Manufactured
default
0.0
Speed control
P03-10
ACCEL Time
Unit
ms
Setting range
0.0 ~ 90000.0
Manufactured
default
0.0
Speed control
P03-11
DECEL Time
Unit
ms
Setting range
0.0 ~ 90000.0
Manufactured
default
0.0
Speed control
P03-12*
S-Mode TC
Unit
ms
Setting range
0.0 ~ 9000.0
Manufactured
default
0.0
Speed control
P03-13
In Speed Range
Unit
rpm
Setting range
0.0 ~ 9999.9
Manufactured
default
10.0
Speed control
P03-14
Zero Speed Range
Unit
rpm
Setting range
0.0 ~ 9999.9
Manufactured
default
10.0
Speed control
P03-15*
+ 10[V] RPM
Unit
rpm
Setting range
0.0 ~ 9999.9
Manufactured
default
Applied motor
rated speed
Speed/Torque
control
This sets the command speed range of the +10[V] analog voltage when the servo drive is in
speed control or torque control mode.
Set speed
(P03-15)
Voltage
Summary of Contents for FDA7000 Series
Page 42: ...1 Model check and handling 1 35...
Page 57: ...2 Wiring and connection 2 14 Drawing C Order Code Please contact our sales office...
Page 130: ...3 Parameter setting 3 51...
Page 167: ...5 Servo operating 5 10...
Page 188: ...8 External view 8 2 External view B CN1 CN3 CN2 External view C...
Page 189: ...8 External view 8 3 External view D External view E...
Page 190: ...8 External view 8 4 External view F External view G...
Page 192: ...8 External view 8 6 External view I External view J...
Page 193: ...8 External view 8 7 External view K External view L...
Page 194: ...8 External view 8 8 External view M...
Page 195: ...8 External view 8 9...