2-36
888-2517-001
1/3/05
WARNING: Disconnect primary power prior to servicing.
eCDi ™
Section 2 Installation & Setup
STEP 23
If you are using SNMP v3 (version 3) then User Names and Passwords
must be entered for each user. Simply type the User Name and Password
into the text boxes and press Submit. Users may be deleted by using the
delete user pull down menu. To edit a user requires that it simply be
deleted and re-entered.
STEP 24
Next select the type of security functionality to be used by selecting
either “MD5 & DES” for authentication and encryption or select
“Noauth and Noenc” for no authorization or encryption.
STEP 25
Lastly, select the V3 only checkbox to prevent V1 and V2 logins that
would bypass the username and password security of V3.
Figure 2-27 SNMP v3 Setup
STEP 26
When all changes are made, press Submit and then press Back to return
to the main menu. Click on Email to access the screen in Figure 2-28.
NOTE:
See Section 6 for
additional SNMP
information.