1/3/05
888-2517-001
B-3
WARNING: Disconnect primary power prior to servicing.
Appendix B DiamondCD Fault and
eCDi ™
sys
CAB#EEPROMERROR
Indicates that the EEPROM on the cabinet controller of
PA cabinet # may be faulty. (# = 1-5)
sys
CAB#INTERLOCK
Indicates that the cabinet-level interlock on PA cabinet # is
faulted. (# = 1-5)
sys
CAB#AIRPRESSUREFAULT
Indicates that a low air pressure fault was detected in PA
cabinet #. (# = 1-5)
Table B-2 Diamond Power Supply Faults
Group Fault Log Name
Description
ps
CAB#PSSUMFAULT
Cab # Power Supply Sum Fault
ps
PSCABINETSSUMFAULT
PA Cabinets Power Supply Sum Fault
ps
PSSUMFAULT
Status of the front panel F4 Power Supply LED
Active low
ps
PSSUMWARN
Ps Summary warning
ps
PSSYSSUMFAULT
System Power Supply Sum Fault OR (<list>)
ps
ACFAIL
Indicates that an AC power failure was detected on
the control cabinet
ps
PSBFAIL
Indicates failure of low voltage power supply B
ps
PSAFAIL
Indicates failure of low voltage power supply A
ps
CAB#ACFAIL
Indicates an AC power failure was detected on PA
cabinet #.
ps
CAB#PS12VFAULT
+12Vdc fault on Cabinet Controller bd. of Cabinet #
ps
CAB#PHASELOSS
Low or missing AC mains phase in PA Cabinet #
ps
CAB#LOVOLTSUPPLY2FLT
Indicates that low-voltage logic power supply 2 in PA
cabinet # is faulty.
ps
CAB#LOVOLTSUPPLY#FLT
Indicates that low-voltage logic power supply # in PA
cabinet # is faulty.
ps
PSSUMFAULT
Status of the front panel F4 Power Supply LED
Active low
Table B-1 Diamond System Faults
Group Fault Log Name
Description
Summary of Contents for eCDi
Page 4: ...MRH 2 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...
Page 6: ...vi 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...
Page 8: ...viii 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...
Page 12: ...xii 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...