B-8
888-2517-001
1/3/05
WARNING: Disconnect primary power prior to servicing.
eCDi ™
Appendix B DiamondCD Fault and
pa
CAB#MOD#MAGNITUDE
I/Q vector magnitude in module # of PA cabinet #.
Not on GUI. No unit of measure.
Cnt
pa
CAB#MOD#FREQUENCY
RF channel frequency of module # of PA cabinet #.
MHz
pa
CAB#MOD#REJECTPWR
Reject power of module # of PA cabinet #.
%
pa
CAB#MOD#PHASECORR
Phase correction voltage applied by cabinet
controller of cabinet # to module #.
mV
Output Meters
out
OUTREFLECTIONFACTOR
Factor reflPwr/fwdPwr in dB/10 (formula: dB/10 =
100 * log (outReflectedPower/
outForwardPower))Attention: result is a negative
number
cB
out
FORWARDPOWERVOLTS
Control Cabinet forward power detector output
mV
out
REFLECTEDPOWERVOLTS
Control Cabinet reflected power detector output
mV
out
FORWARDPOWER
Total System forward power output
mW
out
REFLECTEDPOWER
Total system reflected power output
mW
out
REJECTLOAD#POWER
Power reading for Cabinet combiner reject load #
%
out
CAB#POWERBALANCE
Cabinet # power balance. Indicates gain setting of
the modules in this cabinet. Raw reading, no units.
Cnt
out
CAB#FORWARDPOWER
Forward power reading for PA Cabinet #
W
out
CAB#REFLECTEDPOWER
Reflected power reading for PA Cabinet #
W
Drive Meters
drv
DRV#RFSAMPLE
Forward power reading for Driver #
mW
drv
DRV#CURRENT
Current reading for Driver #
mA
drv
DRV#TEMPERATURE
Temperature reading for Driver #
C
drv
DRV#PSSAMPLE
+28Vdc Driver # PS Sample
mV
drv
DRVPOWERVOLTS
Control Cabinet Drive output detector voltage
mV
drv
DRVPOWER
Control Cabinet Drive output power
mW
drv
EXCITERFOLDBACKLEVEL Foldback control line voltage level. Value of 1023 =
4.8V (approx).
mV
drv
CAB#INPUTPOWER
“Input drive power reading in PA cabinet #
mW
Table B-6 Diamond Meter Log Reference (all meters included)
Group
Meter Log Name
Description
Units
Summary of Contents for eCDi
Page 4: ...MRH 2 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...
Page 6: ...vi 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...
Page 8: ...viii 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...
Page 12: ...xii 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...