C-8
888-2517-001
1/3/05
WARNING: Disconnect primary power prior to servicing.
eCDi ™
Appendix C Atlas Fault and Meter Log
Power Amplifier Meters
pa
PAM#CAB#MODULEALC
Level the Automatic Level Contol is set to for this module Cnt
pa
PAM#CAB#ALCANALOG
ALC offset
Cnt
pa
PAM#CAB#INPUTPWR
Module input power level in micro watts
uW
pa
PAM#CAB#OUTPUTPWR
Module output power level in 100 milliwatt steps
mW
pa
PAM#CAB#REFLECTEDPWR
Module reflected power level in 100 milliwatt steps
mW
pa
PAM#CAB#PREAMPCURR Module pre-amp current in milliamps
mA
pa
PAM#CAB#PREDRVCURR
Module pre-driver current in milliamps
mA
pa
PAM#CAB#DRV1CURRENT Module driver 1 current in milliamps
mA
pa
PAM#CAB#DRV2CURRENT Module driver 2 current in milliamps
mA
pa
PAM#CAB#PAL1CURR
Module pallet 1 current in milliamps
mA
pa
PAM#CAB#PAL2CURR
Module pallet 2 current in milliamps
mA
pa
PAM#CAB#PAL3CURR
Module pallet 3 current in milliamps
mA
pa
PAM#CAB#PAL4CURR
Module pallet 4 current in milliamps
mA
pa
PAM#CAB#PAL5CURR
Module pallet 5 current in milliamps
mA
pa
PAM#CAB#PAL6CURR
Module pallet 6 current in milliamps
mA
pa
PAM#CAB#PAL7CURR
Module pallet 7 current in milliamps
mA
pa
PAM#CAB#PAL8CURR
Module pallet 8 current in milliamps
mA
pa
PAM#CAB#PSVOLTAGE
Module power supply voltage (before switch) in
millivolts
mV
pa
PAM#CAB#FETVOLTAGE1 Module FET voltage 1 (after switch) in millivolts
mV
pa
PAM#CAB#FETVOLTAGE2 Module FET voltage 2 (after switch) in millivolts
mV
pa
PAM#CAB#HTSINKTEMP
Module heat sink temperature in 1/10 degrees Celsius
C
pa
PAM#CAB#SWBRDTEMP
Module switch board temperature in 1/10 degrees Celsius C
pa
PAM#CAB#CTRLBRDTEMP Module control board temperature in 1/10 degrees Celsius C
Output Meters
out
OUTREFLECTIONFACTOR Factor reflPwr/fwdPwr in dB/10 (formula: dB/10 = 100 *
log (outReflectedPower/outForwardPower))Attention:
result is a negative number
cB
out
RFMCAB#REJECTLOAD1
Reject load 1 level. Relative ten bit DAC count
Cnt
out
RFMCAB#REJECTLOAD2
Reject load 2 level. Relative ten bit DAC count
Cnt
out
RFMCAB#REJECTLOAD3
Reject load 3 level. Relative ten bit DAC count
Cnt
out
RFMCAB#REJECTLOAD4
Reject load 4 level. Relative ten bit DAC count
Cnt
out
RFMCAB#REJECTLOAD5
Reject load 5 level. Relative ten bit DAC count
Cnt
Table C-6 Atlas Meter Log Readings
Group Meter Log Name
Description
Units
Summary of Contents for eCDi
Page 4: ...MRH 2 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...
Page 6: ...vi 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...
Page 8: ...viii 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...
Page 12: ...xii 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...