Appendix F Platinum Z Fault and Meter Log Reference
eCDi ™
Table F-5 Platinum Z RF Drive Faults
Group
Fault Log Name
Fault Description
drv
DRVSUMFAULT
Status of the front panel F1 Drive Chain LED Active low
drv
DRVSUMWARNING
Drv sum warning
drv
EX1FAULT
“Exciter1 fault.Enum: 0=Ok,1=Fault”
drv
EX1LOWFAULT
“Exciter1 low fault.Enum: 0=Ok,1=Fault”
drv
EX2FAULT
“Exciter2 fault.Enum: 0=Ok,1=Fault”
drv
EX2LOWFAULT
“Exciter2 low fault.Enum: 0=Ok,1=Fault”
drv
EXCITERFAULT
“Exciter fault. Enum: 0=Ok,1=Fault”
drv
IPAAB1LOWFAULT
“IPA AB1 Low Fault.Enum: 0=Ok,1=Fault”
drv
IPAAB1OUTFAULT
“IPA AB1 out fault.Enum: 0=Ok,1=Fault”
drv
IPAAB1OVERCURRFAULT
“IPA AB1 Over Current Fault.Enum: 0=Ok,1=Fault”
drv
IPAAB1OVERTEMPFAULT
“IPA AB1 Over Temp Fault.Enum: 0=Ok,1=Fault”
drv
IPAAB2LOWFAULT
“IPA AB2 Low Fault.Enum: 0=Ok,1=Fault”
drv
IPAAB2OUTFAULT
“IPA AB2 out fault.Enum: 0=Ok,1=Fault”
drv
IPAAB2OVERCURRFAULT
“IPA AB2 Over Current Fault.Enum: 0=Ok,1=Fault”
drv
IPAAB2OVERTEMPFAULT
“IPA AB2 Over Temp Fault.Enum: 0=Ok,1=Fault”
drv
IPAABSUMFAULT
Ipa AB 1 Ipa Sum Fault
drv
IPAABTEMPWARNING
“IPA AB temp warning.Enum: 0=Ok,1=Warning”
drv
IPACD1LOWFAULT
“IPA CD1 Low Fault.Enum: 0=Ok,1=Fault”
drv
IPACD1OUTFAULT
“IPA CD1 out fault.Enum: 0=Ok,1=Fault”
drv
IPACD1OVERCURRFAULT
“IPA CD1 Over Current Fault.Enum: 0=Ok,1=Fault”
drv
IPACD1OVERTEMPFAULT
“IPA CD1 Over Temp Fault.Enum: 0=Ok,1=Fault”
drv
IPACD2LOWFAULT
“IPA CD2 Low Fault.Enum: 0=Ok,1=Fault”
drv
IPACD2OUTFAULT
“IPA CD2 out fault.Enum: 0=Ok,1=Fault”
drv
IPACD2OVERCURRFAULT
“IPA CD2 Over Current Fault.Enum: 0=Ok,1=Fault”
drv
IPACD2OVERTEMPFAULT
“IPA CD2 Over Temp Fault.Enum: 0=Ok,1=Fault”
drv
IPACDSUMFAULT
Ipa CD 1 Ipa Sum Fault
drv
IPACDTWFAULT
“IPA CD temp warning.Enum: 0=Ok,1=Fault”
drv
IPAFAULT
“IPA fault.Enum: 0=Ok,1=Fault”
drv
IPALOADFAULT
“IPA load fault.Enum: 0=Ok,1=Fault”
drv
IPAMUTEFAULT
“IPA mute fault.Enum: 0=Ok,1=Fault”
drv
MASTERREFFAULT
“Master Reference Fault.Enum: 0=Ok,1=Fault”
drv
PREC1COMMFAULT
Precorrector1 communication fault
drv
PREC1FWDPWROVERPWR
Precorrector1 fwd power over power (latched)
drv
PREC1INPUTOVERPWR
Precorrector1 input over power (latched)
drv
PREC1LOWRFOUT
Precorrector1 low RF out (latched)
Summary of Contents for eCDi
Page 4: ...MRH 2 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...
Page 6: ...vi 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...
Page 8: ...viii 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...
Page 12: ...xii 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...