1/3/05
888-2517-001
B-5
WARNING: Disconnect primary power prior to servicing.
Appendix B DiamondCD Fault and
eCDi ™
pa
CAB#MOD#PAL4OVERCUR
Indicates that pallet 4 of module # of PA cabinet # is
drawing too much current.
pa
CAB#MOD#PAL3OVERCUR
Indicates that pallet 3 of module # of PA cabinet # is
drawing too much current.
pa
CAB#MOD#PAL2OVERCUR
Indicates that pallet 2 of module # of PA cabinet # is
drawing too much current.
pa
CAB#MOD#PAL1OVERCUR
Indicates that pallet 1 of module # of PA cabinet # is
drawing too much current.
pa
CAB#MOD#DRVLDMOSFLT
Indicates that an LDMOS FET has failed on the driver
pallet of module # of PA cabinet #.
pa
CAB#MOD#PAL6LDFLT
Indicates that an LDMOS FET has failed on pallet 6 of
module # of PA cabinet #.
pa
CAB#MOD#PAL5LDFLT
Indicates that an LDMOS FET has failed on pallet 5 of
module # of PA cabinet #.
pa
CAB#MOD#PAL4LDFLT
Indicates that an LDMOS FET has failed on pallet 4 of
module # of PA cabinet #.
pa
CAB#MOD#PAL3LDFLT
Indicates that an LDMOS FET has failed on pallet 3 of
module # of PA cabinet #.
pa
CAB#MOD#PAL2LDFLT
Indicates that an LDMOS FET has failed on pallet 2 of
module # of PA cabinet #.
pa
CAB#MOD#PAL1LDFLT
Indicates that an LDMOS FET has failed on pallet 1 of
module # of PA cabinet #.
Table B-4 Diamond Output Faults
Group Fault Log Name
Description
out
CAB#OUTSUMFAULT
Cab # Output Sum Fault
out
OUTCABINETSSUMFAULT
Cabinets Output Sum Fault OR (cab#OutSumFault)
out
OUTSUMFAULT
Status of the front panel F3 Output LED Active low
out
OUTSUMWARN
Output sum warning
out
REJECT1OVERLOAD
Only if there are >= 2 cabinets
out
REFLECTEDPOWERFAULT
Reflected power above limit
out
FORWARDPOWEROVERLOAD Forward power above 120%
out
VSWRFOLDBACK
Transmitter power is reduced due to system output VSWR
out
CAB#POWERFAULT
out
CAB#REFLECTEDPWRTRIP
Cabinet # Reflected power is above limit
Table B-3 Diamond PA Faults
Group Fault Log Name
Description
Summary of Contents for eCDi
Page 4: ...MRH 2 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...
Page 6: ...vi 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...
Page 8: ...viii 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...
Page 12: ...xii 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...