pa
PA1TOTALCURRENT
PA1 total current in tenths Amp
mA
Output Meters
out
OUTFWDPWRPERCENT
Transmitter forward power as a percentage of
nomPower
%
out
OUTREFLECTIONFACTOR
Factor reflPwr/fwdPwr in dB/10 (formula: dB/10 =
100 * log (outReflectedPower/outForwardPower))
Attention: result is a negative number
cB
out
RFMFOLDBACKLEVEL
Relative foldback level 8 bit count
Cnt
out
RFMREJECTLOAD1
Reject load 1 level. Relative ten bit DAC count
Cnt
out
RFMREJECTLOAD2
Reject load 2 level. Relative ten bit DAC count
Cnt
out
RFMREJECTLOAD3
Reject load 3 level. Relative ten bit DAC count
Cnt
out
RFMFLTRRFCPWR
Prefilter reflected RF power in 1/100 Watts
mW
out
OUTREFLECTEDPOWER
System reflected RF power in 1/100 Watts
mW
out
RFMFLTRFFWDPWR
Prefilter forward RF power in Watts
W
out
OUTFORWARDPOWER
System forward RF power in W
mW
out
RFMVSWRRFLTR
Prefilter VSWR /1000
Cnt
out
OUTVSWR
System VSWR /1000
Cnt
Drive Meters
drv
RFMDRIVERA
Driver A power in 1/10 mWatts
mW
Table D-2 Ranger Meter Log Reference
Group
Meter Log Name
Description
Units
Summary of Contents for eCDi
Page 4: ...MRH 2 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...
Page 6: ...vi 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...
Page 8: ...viii 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...
Page 12: ...xii 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...