B-4
888-2517-001
1/3/05
WARNING: Disconnect primary power prior to servicing.
eCDi ™
Appendix B DiamondCD Fault and
Table B-3 Diamond PA Faults
Group Fault Log Name
Description
pa
CAB#MOD#SUMFAULT
There is a fault in PA Module # of PA Cabinet #
pa
CAB#PASUMFAULT
There is a PA fault somewhere in PA Cabinet #
pa
PASUMFAULT
Status of the front panel F2 Power Amp LED Active low
pa
PASUMWARN
PA summary warning
pa
CAB#MOD#FREQFAULT
Indicates that the reported frequency
(cab#Mod#Frequency) of module # of PA cabinet # does
not match the reported frequency band (cab#Mod#Band).
pa
CAB#MOD#OFFFAULT
Indicates that module # of PA cabinet # is OFF when it
should be ON.
pa
CAB#MOD#CANCOMFLT
Indicates that the Main Controller has lost communication
with module # of PA cabinet #.
pa
CAB#MOD#POSFLT
Indicates that module # of PA cabinet # is not fully
plugged into the cabinet.
pa
CAB#MOD#EEPROMFAIL
Indicates that module # of PA cabinet # was unable to
write to the EEPROM on the module controller.
pa
CAB#MOD#FAILURE12V
Indicates a 12V failure in module # of PA cabinet #.
pa
CAB#MOD#VSWRFAULT
Indicates that the VSWR level in module # of PA cabinet #
is too high.
pa
CAB#MOD#AGCUNLKFLT
Indicates that the AGC circuit in module # of PA cabinet #
is unlocked.
pa
CAB#MOD#REFFLT
Indicates that the reference voltage in module # of PA
cabinet # is out of tolerance.
pa
CAB#MOD#INPUTLOW
Indicates low RF input to module # of PA cabinet #.
pa
CAB#MOD#OVERDRIVE
Indicates that module # of PA cabinet # has detected too
much RF drive power.
pa
CAB#MOD#OVERTEMP
Indicates that module # of PA cabinet # has passed its
heatsink temperature limit.
pa
CAB#MOD#OVERCURR
Indicates that module # of PA cabinet # has drawn too
much current.
pa
CAB#MOD#UNDERVOLTS
Indicates that the RF power supply voltage in module # of
PA cabinet # is too low.
pa
CAB#MOD#OVERVOLTS
Indicates that the RF power supply voltage in module # of
PA cabinet # is too high.
pa
CAB#MOD#DRVOVERCURR
Indicates that the driver pallet of module # of PA cabinet #
is drawing too much current.
pa
CAB#MOD#PAL6OVERCUR
Indicates that pallet 6 of module # of PA cabinet # is
drawing too much current.
pa
CAB#MOD#PAL5OVERCUR
Indicates that pallet 5 of module # of PA cabinet # is
drawing too much current.
Summary of Contents for eCDi
Page 4: ...MRH 2 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...
Page 6: ...vi 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...
Page 8: ...viii 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...
Page 12: ...xii 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...