2-8
888-2517-001
1/3/05
WARNING: Disconnect primary power prior to servicing.
eCDi ™
Section 2 Installation & Setup
There are 2 versions of Control Cabinet for the SigmaCD transmitter.
a.
In the newer style cabinet
the exciter serial
connections are already extended to the Cus-
tomer I/O panel in the top rear area of the
Control Cabinet. Connect the “Y” splitter
cable to the Exciter A and Exciter B connec-
tions (both are male D connectors) on the
Customer I/O Panel and then connect the
eCDi™ serial cable (female to male) to the
“Y” cable as shown in Figure 2-5 (at right).
b.
In older style cabinets
, the exciter serial port
extension cables connect to the System I/O
Board behind the customer I/O Panel, see Fig-
ure 2-6A. In this case, disconnect the 2 serial
cables, labeled 76 and 77 (both are male D
connectors), from the System I/O Board and
connect the “Y” cable directly to the end of
the serial cables. Two (2) standoff kits are pro-
vided to allow the exciter cables and the Y
adaptor to be connected together. Then con-
nect the eCDi™ serial cable (female to male)
to the “Y” connector. The completed assem-
bly is shown in Figure 2-6B.
Figure 2-5 Serial Connection
for Dual CD-1A Exciters
(newer style cabinet)
Figure 2-6 Serial Connection for Dual CD-1A Exciters (older cabinets)
Y Adaptor with Stand-offs
(A)
(B)
1. Remove cables from
System I/O Board.
2. Add stand-off kits to
the Y adaptor cable and
connect to the exciter
cables that were just
removed.
3. Connect Y adaptor to
eCDi™ Exciter cable.
Summary of Contents for eCDi
Page 4: ...MRH 2 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...
Page 6: ...vi 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...
Page 8: ...viii 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...
Page 12: ...xii 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...