F-2
888-2517-001
1/3/05
WARNING: Disconnect primary power prior to servicing.
eCDi ™
Appendix F Platinum Z Fault and Meter Log Reference
F.2
Fault Log Reference
Table F-1 Platinum Z System Faults
Group
Fault Log Name
Fault Description
sys
AMBTEMPFAULT
Ambient temperature fault.Enum: 0=Ok,1=Fault
sys
AMBTEMPWARNING
Ambient temperature warning.Enum: 0=Ok,1=Warning
sys
C1COMMFAULT
PA Controller 1 communication fault. Enum: 0=Ok,1=Fault
sys
C2COMMFAULT
PA Controller 2 communication fault. Enum: 0=Ok,1=Fault
sys
C3COMMFAULT
PA Controller 3 communication fault. Enum: 0=Ok,1=Fault
sys
C4COMMFAULT
PA Controller 4 communication fault. Enum: 0=Ok,1=Fault
sys
C1PACOMMFAULT
PA Controller 1 internal communication fault.Enum:
0=Ok,1=Fault
sys
C2PACOMMFAULT
PA Controller 2 internal communication fault.Enum:
0=Ok,1=Fault
sys
C3PACOMMFAULT
PA Controller 3 internal communication fault.Enum:
0=Ok,1=Fault
sys
C4PACOMMFAULT
PA Controller 4 internal communication fault.Enum:
0=Ok,1=Fault
sys
COMMSUMFAULT
PA Controller Communications Summary Fault (OR funtion)
(psc1Comm, psc2Comm, c1paComm, c2paComm, c3paComm,
c4paComm)
sys
COOLINGSUMFAULT
Cooling Summary Fault OR (ambTemp, lowAir, temp,
thermistor)
sys
COUPLERNCFAULT
Coupler not connected fault.Enum: 0=Ok,1=Fault
sys
DATASOURCEOFFLINE
TX,Ex connection lost
sys
EVENTDESCRIPTION
SNMP trap description
sys
EVENTDESCRIPTION2
SNMP trap description
sys
EVENTINDEX
used as running index for traps so that the manager knows that he
did not miss any
sys
EVENTINDEX2
used as running index for traps so that the manager knows that he
did not miss any
sys
EVENTPRIORITY
SNMP trap priority (fault, warning)
sys
EVENTPRIORITY2
SNMP trap priority (fault, warning)
sys
EXTINTERLOCKFAULT
Ext Interlock Open. Enum: 0=Closed,1=Open
sys
EXTINTERLOCKFAULT1 Ext Interlock Open. Enum: 0=Closed,1=Open (Redundant with
extInterlockFault)
sys
FAILSAFEFAULT
Failsafe. Enum: 0=Ok,1=Fault
sys
LOWAIRFAULT
Low Air Fault.Enum: 0=Ok,1=Fault
sys
MUTE
Transmitter muted: Enum: 0=On,1=Mute
Summary of Contents for eCDi
Page 4: ...MRH 2 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...
Page 6: ...vi 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...
Page 8: ...viii 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...
Page 12: ...xii 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...