WARNING: Disconnect primary power prior to servicing.
Appendix A SigmaCD Fault and Meter
eCDi ™
Table A-5 SigmaCD Diamond Drive IPA Faults
Group Fault Log
Entry
Description
drv
CAB1MODULEOFFFAULT
Indicates that module of PA cabinet 1 is OFF when it should
be ON.
drv
CAB1MODULEFREQFAULT
Indicates that the reported frequency (cab1Mod2Frequency)
of module of PA cabinet 1 does not match the reported
frequency band (cab1Mod2Band).
drv
CAB1FAILURE12V
Indicates a 12V failure in module of PA cabinet 1.
drv
CAB1VSWRFAULT
Indicates that the VSWR level in module of PA cabinet 1 is
too high.
drv
CAB1MODULEPOSFAULT
Indicates that module of PA cabinet 1 is not fully plugged
into the cabinet.
drv
CAB1EEPROMFAIL
Indicates that module of PA cabinet 1 was unable to write to
the EEPROM on the module controller.
drv
CAB1MODULECANCOMFLT Indicates that the Main Controller has lost communication
with module of PA cabinet 1.
drv
CAB1MODULEOVERTEMP
Indicates that module of PA cabinet 1 has passed its heatsink
temperature limit.
drv
CAB1REFERENCEFAULT
Indicates that the reference voltage in module of PA cabinet
1 is out of tolerance.
drv
CAB1AGCUNLOCKFAULT
Indicates that the AGC circuit in module of PA cabinet 1 is
unlocked.
drv
CAB1MODULEOVERVOLT
Indicates that the RF power supply voltage in module of PA
cabinet 1 is too high.
drv
CAB1MODULEUNDERVOLT Indicates that the RF power supply voltage in module of PA
cabinet 1 is too low.
drv
CAB1MODULEOVERDRIVE
Indicates that module of PA cabinet 1 has detected too much
RF drive power.
drv
CAB1MODULEOVERCURR
Indicates that module of PA cabinet 1 has drawn too much
current.
drv
CAB1MODULEINPUTLOW
Indicates low RF input to module of PA cabinet 1.
drv
CAB1PALLET4OVERCURR
Indicates that pallet 4 of module of PA cabinet 1 is drawing
too much current.
drv
CAB1PALLET5OVERCURR
Indicates that pallet 5 of module of PA cabinet 1 is drawing
too much current.
drv
CAB1PALLET6OVERCURR
Indicates that pallet 6 of module of PA cabinet 1 is drawing
too much current.
drv
CAB1PALLET3OVERCURR
Indicates that pallet 3 of module of PA cabinet 1 is drawing
too much current.
Summary of Contents for eCDi
Page 4: ...MRH 2 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...
Page 6: ...vi 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...
Page 8: ...viii 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...
Page 12: ...xii 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...