Operation Manual – Information Center
H3C S3610&S5510 Series Ethernet Switches
Chapter 1 Information Center Configuration
1-13
To do…
Use the command…
Remarks
Configure the channel
through which system
information can be output
to the SNMP NMS
info-center snmp
channel
{
channel
-
number |
channel
-
name
}
Optional
System information is
output to the SNMP NMS
by default with channel 5
(known as snmpagent) as
the default channel.
Configure the output rules
of the system information
info-center source
{
module
-
name
|
default
}
channel
{
channel
-
number |
channel
-
name
} [
debug
{
level
severity
|
state
state
} * |
log
{
level
severity
|
state
state
} * |
trap
{
level
severity
|
state
state
} * ] *
Optional
output rules of the system
information.
Configure the format of
the timestamp
info-center timestamp
{
debugging
|
log
|
trap
}
{
boot
|
date
|
none
}
Optional
The time stamp for log,
trap and debug
information is
date
by
default.
Note:
To ensure that system information can be output to the SNMP NMS, you need to make
the necessary configurations on the SNMP agent and the NMS. For detailed
information on SNMP, refer to the
SNMP-RMON Configuration
part of the manual.
1.2.8 Configuring Synchronous Information Output
Synchronous information output refers to the feature that if the user’s input is
interrupted by system output such as log, trap, or debugging information, then after the
completion of system output the system will display a command line prompt (in
command editing mode a prompt, or a [Y/N] string in interaction mode) and your input
so far.
This command is used in the case that your input is interrupted by a large amount of
system output. With this feature enabled, you can continue your operations from where
you were stopped.