Operation Manual – NTP
H3C S3610&S5510 Series Ethernet Switches
Chapter 1 NTP Configuration
1-30
Now, Switch D can receive broadcast messages through VLAN-interface 2, and Switch
C can send broadcast messages through VLAN-interface 2. Upon receiving a
broadcast message from Switch C, Switch D synchronizes its clock to that of Switch C.
# View the NTP status of Switch D after clock synchronization.
[SwitchD] display ntp-service status
Clock status: synchronized
Clock stratum: 4
Reference clock ID: 3.0.1.31
Nominal frequency: 100.0000 Hz
Actual frequency: 100.0000 Hz
Clock precision: 2^7
Clock offset: 0.0000 ms
Root delay: 31.00 ms
Root dispersion: 8.31 ms
Peer dispersion: 34.30 ms
Reference time: 16:01:51.713 UTC Apr 20 2007 (C6D95F6F.B6872B02)
As shown above, Switch D has been synchronized to Device B, and the clock stratum
level of Switch D is 3, while that of Switch C is 2.
# View the NTP session information of Switch D, which shows that an association has
been set up between Switch D and Switch C.
[SwitchD] display ntp-service sessions
source reference stra reach poll now offset delay disper
**************************************************************************
[1234] 3.0.1.31 127.127.1.0 3 254 64 62 -16.0 32.0 16.6
note: 1 source(master),2 source(peer),3 selected,4 candidate,5 configured
Total associations : 1