Operation Manual – VLAN
H3C S3610&S5510 Series Ethernet Switches
Chapter 3 GVRP Configuration
3-7
Table 3-2
Dependencies of GARP timers
Timer
Lower limit
Upper limit
Hold
10 centiseconds
Not greater than half of the
join timer setting
Join
Not less than two times the hold
timer setting
Less than half of the leave
timer setting
Leave
Greater than two times the join timer
setting
Less than the LeaveAll timer
setting
LeaveAll
Greater than the leave timer setting
32765 centiseconds
3.4 Displaying and Maintaining GVRP
To do…
Use the command…
Remarks
Display statistics about
GARP
display garp statistics
[
interface
interface-list
]
Available in any
view
Display GARP timers for
specified or all ports
display garp timer
[
interface
interface-list
]
Available in any
view
Display the local VLAN
information maintained by
GVRP
display gvrp local-vlan
interface
interface-type
interface-number
Available in any
view
Display the current GVRP
state
display gvrp state
interface
interface-type interface-number
vlan
vlan-id
Available in any
view
Display statistics about
GVRP
display gvrp statistics
[
interface
interface-list
]
Available in any
view
Display the global GVRP
state
display gvrp status
Available in any
view
Display the information
about dynamic VLAN
operations performed on
a port
display gvrp vlan-operation
interface
interface-type
interface-number
Available in any
view
Clear the GARP statistics
reset garp statistics
[
interface
interface-list
]
Available in user
view