300
Multiviewer SDC
System - Setup
Software Version
Shows the currently installed Multiviewer SDC software version
number.
Build Number
Shows the build number of the currently installed Multiviewer SDC
software.
System Reset
Reboots the UCP
-
3901 Card. This is used to make any
System-Setup
template configuration setting changes take effect. Performing a
system reset makes the multiviewer use the new settings.
A system reset reboots the multiviewer by
effectively
powering it
down and then powering it back up: This will produce a picture
disturbance on all multiviewer head display outputs and network
connections.
A reboot takes approximately 75 seconds.
RollCall Settings
The RollCall settings in the
System-Setup
template are used to allow
Grass Valley Orbit software applications to control the Multiviewer
SDC and should normally be changed if you have multiple
Multiviewer SDC running on UCP
-
3901 Cards on the same RollCall
network.
RollCall Network
Enter the RollCall network number. The network number forms part of
the unit’s RollCall address; this is
not
an IP network address.
, on page 301 for more information.
RollCall Unit
Enter the RollCall unit number. The unit number must be unique for
each Multiviewer being configured. The initial default value is
01
.
, on page 301 for more information.
RollCall Port
This parameter is not used.
RollCall IP Port
This parameter is not used.
Domain ID
, on page 301 for more information.
Output Format
The
Output Format
of
multiviewer head display outputs is set for
all
of the multiviewer display outputs. All outputs share the same format.
Format Selection
Select the display output format.
Note:
4K/UHD Output:
When driving a 4K/UHD monitor, each
Multiviewer SDC head
display output drives one quadrant of the UHD monitor.
Some 4K/UHD monitors have four 1080P inputs, so they can be fed
from four
Multiviewer SDC 1080p outputs. If this is not the case, a
separate adapter must be used to convert four
Multiviewer SDC
display outputs to a single 4K signal suitable for the monitor.
Information Box
These are text fields which allow you to enter the name, location and
notes about your multiviewer unit, for future reference.
To enter/modify text in the text box, type directly into the editable
text field and click
. To return to the default text, click
.
Name
You can give your multiviewer a meaningful name, making it easier to
identify by its role or purpose. Maximum 32 characters. Click
or
press
return
to save the name locally.
Parameter
Description
Summary of Contents for IQUCP25
Page 8: ...8 Notices ...
Page 47: ...47 UCP 3901 User Manual IQUCP2504 2B3 IQUCP2505 3B3 IQUCP5000 2B3 ...
Page 52: ...52 IQUCP Card Installation and Operation Remote control using RollCall ...
Page 58: ...58 Connections and Cabling About HDMI Type Signal Connections ...
Page 70: ...70 Connecting to the Card s Configuration Interface Setting Values in RollCall ...
Page 167: ...167 UCP 3901 User Manual Ethernet Arcnet Not currently used ...
Page 246: ...246 MADI Processing SDC Ethernet Arcnet Ethernet Arcnet Not currently used ...